1 Check the electrical equipment (all kinds of meters) of the vacuum oil filter should be regularly inspected and tested by the testing unit, and can be put into use only after passing the test.
2 Whether the placement of the machine is stable or not, and there is no sway or vibration during the test run.
3 Check whether the inlet and outlet pipes are installed correctly, whether the external pipes are firmly installed, and the joints between the hose and the metal pipe should be fastened with monkey hoops to prevent the oil pipeline from falling off during operation.
4 Check whether the external power supply is correct, and whether the connected power cable can meet the capacity requirements of the oil filter.
5 Check that the machine casing should be grounded reliably.
6 Check that all rotating parts should be free from jamming.
7 Carry out a trial run to check that the steering of the oil pump, vacuum pump and other motors should meet the requirements.
8 Check whether the cooling water connection is reliable, and the waterway should be unblocked.
9 Check whether the fire extinguishing equipment configured on site meets the requirements.